Siemens SM110 / SM100 solar module: datasheet and specifications
110 Wrated power
17.5 VVmp
21.7 VVoc
11.5 kgweight
1316 × 660 mmoutline
Siemens SM110 / SM100: product photograph restored from the original low-resolution picture.
The SM110 and SM100 are the large single-crystal modules: 72 cells, 1316 × 660 mm, 11.5 kg and 110 W or 100 W. They were offered framed (F) and as a laminate (L), in 12 V and, as the SM110-24 and SM100-24, in 24 V versions. Siemens’ pitch was fewer modules for a given power, so fewer attachment points, terminal boxes and connections.
Electrical data
72 cells in series; single-crystal silicon.
Parameter
SM110 (12 V)
SM110-24 (24 V)
SM100 (12 V)
SM100-24 (24 V)
Rated power Pmax (W)
110
110
100
100
Minimum power Pmin (W)
100
100
90
90
Current at Pmax, Imp (A)
6.3
3.15
5.9
2.95
Voltage at Pmax, Vmp (V)
17.5
35
17
34
Short-circuit current, Isc (A)
6.9
3.45
6.5
3.25
Open-circuit voltage, Voc (V)
21.7
43.5
21
42
Derived figures
Quantity
Value
How it was obtained
Outer area
0.869 m²
calculated from length × width
Power per area
127 W/m²
calculated; Pmax ÷ area at STC
Module efficiency
12.7 %
calculated on outer dimensions (cell efficiency is higher)
Power per weight
9.6 W/kg
calculated
Voc at −20 °C (SM110 (12 V))
25.2 V
calculated with the datasheet Voc coefficient
Voc at −20 °C (SM110-24 (24 V))
50.5 V
calculated with the datasheet Voc coefficient
Vmp with 60 °C cells (SM110 (12 V))
14.6 to 15.3 V
approximate range; see the note below the table
Rough daily energy
412 Wh
calculated: Pmax × 5 peak-sun-hours × 0.75 system efficiency; a planning figure, not a measurement
Seventy-two cells in one laminate gives two electrical choices from the same footprint: 12 V (Vmp 17.5 V, 6.3 A) and 24 V (Vmp 35 V, 3.15 A). The 24 V version halves the current, which cuts cable loss over long runs. In 5 peak-sun-hours the 12 V version adds roughly 23.6 Ah a day to a 12 V battery (Imp × 5 h × 0.75).
Full datasheet tables
Thermal
Parameter
Unit
Value
Nominal operating cell temperature (NOC)
°C
45 ± 2
Change of Isc with temperature
+1.2 mA/°C (+0.04 %/K)
Change of Voc with temperature
-0.0775 V/°C (−0.34 %/K)
Qualification tests
Parameter
Unit
Value
Temperature cycling range
°C
−40 to +85
Humidity, freeze, damp heat condition
% RH
85
Maximum system voltage
V
1000 per ISPRA (EC), 600 per UL 1703
Wind loading or surface pressure
N/m² (PSF)
2400 (50)
Maximum distortion (4)
degrees
1.2
Hailstone impact withstand (diameter @ velocity)
mm @ m/s (in @ mph)
25 @ 23 (1.0 @ 52)
Physical
Parameter
Unit
Value
Number of series cells
count
72
Length
mm (in)
1316 (51.8)
Width
mm (in)
660 (25.98)
Depth
mm (in)
40 (1.6)
Weight
kg (lb)
11.5 (25.1)
Warranty (5)
Parameter
Unit
Value
Power ≥ 90 % of minimum power
years
10
Power ≥ 80 % of minimum power
years
25
Notes from the datasheet. (1) Electrical values at standard test conditions: irradiance 1000 W/m², cell temperature 25 °C, spectrum per ASTM E892 (air mass 1.5). (2) Nominal operating conditions: 800 W/m², ambient 20 °C, wind 1 m/s. (3) Qualification tests per CEC 503. (4) Diagonal lifting of a module corner with three corners fixed. (5) Warranty applies to the original consumer purchaser; see the full limited warranty for conditions. The tier percentages refer to the minimum power rating (Pmin), not the rated power.
Where Siemens recommended it
The Siemens application pages list this module for: architectural and utility systems. See the case files for installations from those categories.