Siemens SM110 / SM100 solar module: datasheet and specifications

110 Wrated power
17.5 VVmp
21.7 VVoc
11.5 kgweight
1316 × 660 mmoutline
Siemens SM110 / SM100 solar module
Siemens SM110 / SM100: product photograph restored from the original low-resolution picture.

The SM110 and SM100 are the large single-crystal modules: 72 cells, 1316 × 660 mm, 11.5 kg and 110 W or 100 W. They were offered framed (F) and as a laminate (L), in 12 V and, as the SM110-24 and SM100-24, in 24 V versions. Siemens’ pitch was fewer modules for a given power, so fewer attachment points, terminal boxes and connections.

1316 mm (51.8 in)660 mm(26.0 in)Depth 40 mm · outline to scale · cell layout as in the module photographPmax point: 17.5 V, 6.3 AIsc 6.9 AVoc 21.7 V110 W at Pmax■ Current (A)■ Power (W)Voltage (V)

Electrical data

72 cells in series; single-crystal silicon.

ParameterSM110 (12 V)SM110-24 (24 V)SM100 (12 V)SM100-24 (24 V)
Rated power Pmax (W)110110100100
Minimum power Pmin (W)1001009090
Current at Pmax, Imp (A)6.33.155.92.95
Voltage at Pmax, Vmp (V)17.5351734
Short-circuit current, Isc (A)6.93.456.53.25
Open-circuit voltage, Voc (V)21.743.52142

Derived figures

QuantityValueHow it was obtained
Outer area0.869 m²calculated from length × width
Power per area127 W/m²calculated; Pmax ÷ area at STC
Module efficiency12.7 %calculated on outer dimensions (cell efficiency is higher)
Power per weight9.6 W/kgcalculated
Voc at −20 °C (SM110 (12 V))25.2 Vcalculated with the datasheet Voc coefficient
Voc at −20 °C (SM110-24 (24 V))50.5 Vcalculated with the datasheet Voc coefficient
Vmp with 60 °C cells (SM110 (12 V))14.6 to 15.3 Vapproximate range; see the note below the table
Rough daily energy412 Whcalculated: Pmax × 5 peak-sun-hours × 0.75 system efficiency; a planning figure, not a measurement

Seventy-two cells in one laminate gives two electrical choices from the same footprint: 12 V (Vmp 17.5 V, 6.3 A) and 24 V (Vmp 35 V, 3.15 A). The 24 V version halves the current, which cuts cable loss over long runs. In 5 peak-sun-hours the 12 V version adds roughly 23.6 Ah a day to a 12 V battery (Imp × 5 h × 0.75).

Full datasheet tables

Thermal

ParameterUnitValue
Nominal operating cell temperature (NOC)°C45 ± 2
Change of Isc with temperature+1.2 mA/°C (+0.04 %/K)
Change of Voc with temperature-0.0775 V/°C (−0.34 %/K)

Qualification tests

ParameterUnitValue
Temperature cycling range°C−40 to +85
Humidity, freeze, damp heat condition% RH85
Maximum system voltageV1000 per ISPRA (EC), 600 per UL 1703
Wind loading or surface pressureN/m² (PSF)2400 (50)
Maximum distortion (4)degrees1.2
Hailstone impact withstand (diameter @ velocity)mm @ m/s (in @ mph)25 @ 23 (1.0 @ 52)

Physical

ParameterUnitValue
Number of series cellscount72
Lengthmm (in)1316 (51.8)
Widthmm (in)660 (25.98)
Depthmm (in)40 (1.6)
Weightkg (lb)11.5 (25.1)

Warranty (5)

ParameterUnitValue
Power ≥ 90 % of minimum poweryears10
Power ≥ 80 % of minimum poweryears25

Notes from the datasheet. (1) Electrical values at standard test conditions: irradiance 1000 W/m², cell temperature 25 °C, spectrum per ASTM E892 (air mass 1.5). (2) Nominal operating conditions: 800 W/m², ambient 20 °C, wind 1 m/s. (3) Qualification tests per CEC 503. (4) Diagonal lifting of a module corner with three corners fixed. (5) Warranty applies to the original consumer purchaser; see the full limited warranty for conditions. The tier percentages refer to the minimum power rating (Pmin), not the rated power.

The Siemens application pages list this module for: architectural and utility systems. See the case files for installations from those categories.