Siemens SP18 solar module: datasheet and specifications

18 Wrated power
17 VVmp
21.7 VVoc
2.7 kgweight
633 × 275 mmoutline
Siemens SP18 solar module
Siemens SP18: product photograph restored from the original low-resolution picture.

The SP18 is an 18 W module of 36 cells on a 633 × 275 mm frame (2.7 kg), offered in a 12 V version (Vmp 17.0 V) and a 6 V version (Vmp 8.5 V at twice the current). Siemens listed it for telecom and for gas and oil telemetry.

633 mm (24.9 in)275 mm(10.8 in)Depth 34 mm · outline to scale · cell layout as in the module photographPmax point: 17 V, 1.1 AIsc 1.2 AVoc 21.7 V19 W at Pmax■ Current (A)■ Power (W)Voltage (V)

Electrical data

36 cells in series; silicon (sp series).

ParameterSP18 (12 V)SP18 (6 V)
Rated power Pmax (W)1818
Minimum power Pmin (W)1616
Current at Pmax, Imp (A)1.12.1
Voltage at Pmax, Vmp (V)178.5
Short-circuit current, Isc (A)1.22.4
Open-circuit voltage, Voc (V)21.710.9

Derived figures

QuantityValueHow it was obtained
Outer area0.174 m²calculated from length × width
Power per area103 W/m²calculated; Pmax ÷ area at STC
Module efficiency10.3 %calculated on outer dimensions (cell efficiency is higher)
Power per weight6.7 W/kgcalculated
Voc at −20 °C (SP18 (12 V))25.2 Vcalculated with the datasheet Voc coefficient
Voc at −20 °C (SP18 (6 V))12.6 Vcalculated with the datasheet Voc coefficient
Vmp with 60 °C cells (SP18 (12 V))14.2 to 14.9 Vapproximate range; see the note below the table
Rough daily energy68 Whcalculated: Pmax × 5 peak-sun-hours × 0.75 system efficiency; a planning figure, not a measurement

With 36 cells in series the Vmp is 17 V at 25 °C. With 60 °C cells it falls to about 14.2 to 14.9 V (the datasheet gives no Vmp coefficient: the lower figure assumes a typical −0.47 %/K, the upper scales the Voc coefficient), a margin of -0.2 to +0.5 V against 14.4 V. The margin is negative or marginal, so on hot days this module may not finish charging a lead-acid battery. In 5 peak-sun-hours the 12 V version adds roughly 4.1 Ah a day to a 12 V battery (Imp × 5 h × 0.75).

Full datasheet tables

Thermal

ParameterUnitValue
Nominal operating cell temperature (NOC)°C45
Change of Isc with temperature+2.06 mA/°C (+0.04 %/K)
Change of Voc with temperature-0.077 V/°C (−0.34 %/K)

Qualification tests

ParameterUnitValue
Temperature cycling range°C−40 to +85
Humidity, freeze, damp heat condition% RH85
Maximum system voltageV1000 per ISPRA (EC), 600 per UL 1703
Wind loading or surface pressureN/m² (PSF)2400 (50)
Maximum distortion (4)degrees1.2
Hailstone impact withstand (diameter @ velocity)mm @ m/s (in @ mph)25 @ 23 (1.0 @ 52)

Physical

ParameterUnitValue
Number of series cellscount36
Lengthmm (in)633 (24.9)
Widthmm (in)275 (10.8)
Depthmm (in)34 (1.3)
Weightkg (lb)2.7 (5.9)

Warranty (5)

ParameterUnitValue
Power ≥ 90 % of minimum poweryears10

Notes from the datasheet. (1) Electrical values at standard test conditions: irradiance 1000 W/m², cell temperature 25 °C, spectrum per ASTM E892 (air mass 1.5). (2) Nominal operating conditions: 800 W/m², ambient 20 °C, wind 1 m/s. (3) Qualification tests per CEC 503. (4) Diagonal lifting of a module corner with three corners fixed. (5) Warranty applies to the original consumer purchaser; see the full limited warranty for conditions. The tier percentages refer to the minimum power rating (Pmin), not the rated power.

The Siemens application pages list this module for: telecom, gas and oil. See the case files for installations from those categories.