Siemens SR50 / SR50Z solar module: datasheet and specifications

50 Wrated power
17 VVmp
21.6 VVoc
5.9 kgweight
783 × 594 mmoutline
Siemens SR50 / SR50Z solar module
Siemens SR50 / SR50Z: product photograph restored from the original low-resolution picture.

The SR50 is a squarer 50 W module (783 × 594 mm, 5.9 kg) than the long narrow SM50. It has 36 cells and is offered in 12 V and 6 V versions. The page calls it ‘built for long-term dependability’ with a twenty-five year limited warranty on power output, and its datasheet table carries both tiers: power above 90 % of the minimum for 10 years and above 80 % for 25 years.

783 mm (30.8 in)594 mm(23.4 in)Depth 34 mm · outline to scale · cell layout as in the module photographPmax point: 17 V, 2.95 AIsc 3.2 AVoc 21.6 V50 W at Pmax■ Current (A)■ Power (W)Voltage (V)

Electrical data

36 cells in series; silicon (sr series).

ParameterSR50 (12 V)SR50 (6 V)
Rated power Pmax (W)5050
Minimum power Pmin (W)4545
Current at Pmax, Imp (A)2.955.9
Voltage at Pmax, Vmp (V)178.5
Short-circuit current, Isc (A)3.26.4
Open-circuit voltage, Voc (V)21.610.8

Derived figures

QuantityValueHow it was obtained
Outer area0.465 m²calculated from length × width
Power per area108 W/m²calculated; Pmax ÷ area at STC
Module efficiency10.8 %calculated on outer dimensions (cell efficiency is higher)
Power per weight8.5 W/kgcalculated
Voc at −20 °C (SR50 (12 V))25.2 Vcalculated with the datasheet Voc coefficient
Voc at −20 °C (SR50 (6 V))12.6 Vcalculated with the datasheet Voc coefficient
Vmp with 60 °C cells (SR50 (12 V))14.2 to 14.8 Vapproximate range; see the note below the table
Rough daily energy188 Whcalculated: Pmax × 5 peak-sun-hours × 0.75 system efficiency; a planning figure, not a measurement

With 36 cells in series the Vmp is 17 V at 25 °C. With 60 °C cells it falls to about 14.2 to 14.8 V (the datasheet gives no Vmp coefficient: the lower figure assumes a typical −0.47 %/K, the upper scales the Voc coefficient), a margin of -0.2 to +0.4 V against 14.4 V. The margin is negative or marginal, so on hot days this module may not finish charging a lead-acid battery. In 5 peak-sun-hours the 12 V version adds roughly 11.1 Ah a day to a 12 V battery (Imp × 5 h × 0.75).

Full datasheet tables

Thermal

ParameterUnitValue
Nominal operating cell temperature (NOC)°C45
Change of Isc with temperature+1.1 mA/°C (+0.04 %/K)
Change of Voc with temperature-0.079 V/°C (−0.34 %/K)

Qualification tests

ParameterUnitValue
Temperature cycling range°C−40 to +85
Humidity, freeze, damp heat condition% RH85
Maximum system voltageV1000 per ISPRA (EC), 600 per UL 1703
Wind loading or surface pressureN/m² (PSF)2400 (50)
Maximum distortion (4)degrees1.2
Hailstone impact withstand (diameter @ velocity)mm @ m/s (in @ mph)25 @ 23 (1.0 @ 52)

Physical

ParameterUnitValue
Number of series cellscount36
Lengthmm (in)783 (30.8)
Widthmm (in)594 (23.4)
Depthmm (in)34 (1.34)
Weightkg (lb)5.9 (13.0)

Warranty (5)

ParameterUnitValue
Power ≥ 90 % of minimum poweryears10
Power ≥ 80 % of minimum poweryears25

Notes from the datasheet. (1) Electrical values at standard test conditions: irradiance 1000 W/m², cell temperature 25 °C, spectrum per ASTM E892 (air mass 1.5). (2) Nominal operating conditions: 800 W/m², ambient 20 °C, wind 1 m/s. (3) Qualification tests per CEC 503. (4) Diagonal lifting of a module corner with three corners fixed. (5) Warranty applies to the original consumer purchaser; see the full limited warranty for conditions. The tier percentages refer to the minimum power rating (Pmin), not the rated power.

← SP75 / SP70  ·  All 16 modules  ·  SR100 / SR90 →