Testing an old Siemens solar panel takes two stages. In the first, the module is disconnected and placed in full, unshaded sun, and a multimeter reads its open-circuit voltage (Voc) and short-circuit current (Isc). Both readings are corrected for cell temperature and sunlight and then compared with the datasheet. For an SM55, about 19.8 V at a 50 °C cell and about 2.8 A at roughly 800 W/m² are consistent with intact cells and wiring. The second stage is a load test, and only the load test shows whether power has dropped. Failed solder bonds, a fault reported in aged SM55 modules, can leave Voc and Isc looking normal.
The procedure is the same for modules sold under the ARCO Solar, Siemens Solar and Shell Solar names. This page uses the SM55 as its example because the full datasheet values are published (Chaibi et al., Data in Brief, 2019). For any other model, the label identifies it (how to identify a Siemens solar module), and that model’s datasheet supplies the figures. A1 Solar is an independent archive. It has no tie to Siemens or to the companies that later owned its solar business, and it does not test, repair or warrant modules.
What is needed to test an old solar panel
The conditions below follow PVEducation’s procedure for measuring a module without a load:
- A digital multimeter with a 10 A DC current socket. For the current reading, PVEducation’s instruction is to “Change the power (red) lead to the 10 A socket to prevent blowing the fuse.” For voltage, the 200 V range is the safe setting when the expected value is uncertain.
- A thermometer for the back sheet. An infrared thermometer is the easiest kind to use. PVEducation takes module temperature on the back sheet.
- A clear day, with the module facing the sun. On a cloudy day a module gives “about 10-20% of the rated output,” per PVEducation. The readings would then show the weather, not the module.
- No shade on any part of the module. “Make sure none of the module is shaded.” PVEducation notes that even partial shading causes a large loss.
- The module disconnected from the charge controller, the battery and any other modules.
- A written note of the time and the back-sheet temperature at each reading.
Step 1: Look for the defects old ARCO and Siemens modules are known for
The visual check comes first because a few defects decide the question before any meter is used. The best-documented set comes from CDER in Algeria. CDER examined 64 ARCO Solar modules (43 W nameplate, 36 monocrystalline cells) after about 20 years in the Adrar desert and about 10 more in Algiers (pv magazine, September 2026).

What CDER found on those modules:
- Busbar discoloration and cell browning on all 64. CDER names corrosion and discoloration as the main ways the modules degraded.
- Cracked cells on some.
- Detached junction boxes on some. A junction box that has come loose should be treated as a safety concern.
- Hot spots or thermal anomalies under infrared on about 46%. These are not visible without an infrared camera.
SUPSI’s study of Swiss AM55 and SM55 systems adds an encapsulant finding: “Early-generation encapsulants without UV stabilisation showed accelerated ageing” (pv magazine, January 2026). The published summary does not say which production years used the unstabilized material.
The module’s model has to be confirmed from its label before any reading is compared with a datasheet. An SM50 or an SM75 reading checked against SM55 values will look wrong when nothing is wrong.
Step 2: Measure open-circuit voltage and correct it for temperature
Open-circuit voltage is the reading taken with nothing connected to the module. The meter is set to DC volts. The red lead goes on the positive terminal and the black lead on the negative, with the module facing the sun. The reading, the back-sheet temperature and the time are recorded together, because Voc drops as the module heats up (PVEducation).

The SM55 values at standard test conditions (1000 W/m², 25 °C cell), from Table 1 of Chaibi et al.:
| Model | Pmax (W) | Vmp (V) | Imp (A) | Voc (V) | Isc (A) |
|---|---|---|---|---|---|
| SM55 (Shell datasheet, STC) | 55 | 17.4 | 3.15 | 21.7 | 3.45 |
The same table gives a voltage temperature coefficient of −0.35 %/K, a current coefficient of +0.04 %/K, and 36 cells. The full SM55 and SM50 figures are on the SM55/SM50 datasheet page.
A module in the sun runs well above 25 °C, so the datasheet’s 21.7 V is not the number a healthy SM55 shows on a test day. The expected value at cell temperature T is:
Expected Voc = 21.7 V × (1 − 0.0035 × (T − 25 °C))
At a 50 °C cell: 21.7 V × (1 − 0.0035 × 25) = 21.7 V × 0.9125 ≈ 19.8 V.
PVEducation gives a general rule for silicon: Voc falls by “about 2.2 mV/°C” per cell (Effect of Temperature). Across 36 cells that is about 0.079 V/°C. The datasheet coefficient works out to 0.0035 × 21.7 V ≈ 0.076 V/°C. The two sources do not agree exactly, so both results are printed:
| Cell temperature (°C) | Expected Voc, datasheet −0.35 %/K (V) | Expected Voc, PVEducation 2.2 mV/°C per cell (V) |
|---|---|---|
| 25 | 21.70 | 21.70 |
| 40 | 20.56 | 20.51 |
| 50 | 19.80 | 19.72 |
| 60 | 19.04 | 18.93 |
The largest gap is 0.11 V at 60 °C. That is far smaller than the test’s own error. PVEducation states that “The measurement of VOC will be accurate to within 10%” (PVEducation). At a 50 °C cell, that puts a healthy SM55 anywhere from about 17.8 V to 21.8 V.
The back-sheet reading is used here as the cell temperature. The cells themselves cannot be measured in the field, and none of the sources on this page give the gap between the two. Estimating cell temperature from the weather is less reliable. A module’s nominal operating cell temperature (NOCT) is defined at 800 W/m², 20 °C air, 1 m/s wind and an open back, and “Module temperature will be lower than this when wind velocity is high, but higher under still conditions” (PVEducation, NOCT). The SM55’s NOCT is not in the datasheet table used here.
A low reading carries more information than a normal one. The 36 cells are wired in series, so at a 50 °C cell each one contributes about 19.8 V ÷ 36 ≈ 0.55 V. A shorted bypass diode takes its group of cells out of the string, and Voc falls by that group’s share. The number of cells per bypass diode on the SM55 is not confirmed in the documents used for this page. Wiring Siemens solar modules covers bypass diodes and how they are connected. A reading near 0 V means an open circuit somewhere between the cells and the terminals.
Step 3: Measure short-circuit current and scale it for sunlight
Short-circuit current is the current that flows when the two module leads are connected through the meter. The red lead must first move to the 10 A socket (PVEducation). The meter is set to DC amps and the leads are touched across the terminals long enough to read the value. The SM55’s rated Isc of 3.45 A is well inside a 10 A rating. The red lead goes back to the voltage socket before any further voltage reading.
Isc follows sunlight. The arithmetic below assumes the two are directly proportional. At 800 W/m², the light level used for NOCT, the expected value is 3.45 A × 0.8 = 2.76 A. Heat raises it slightly: +0.04 %/K over 25 K adds about 1%, which gives about 2.79 A at a 50 °C cell.
| Irradiance (W/m²) | Expected SM55 Isc, 25 °C cell (A) | Expected SM55 Isc, 50 °C cell (A) |
|---|---|---|
| 1000 | 3.45 | 3.48 |
| 800 | 2.76 | 2.79 |
| 600 | 2.07 | 2.09 |
| 400 | 1.38 | 1.39 |
| 200 | 0.69 | 0.70 |
PVEducation’s general figure for silicon is about “0.06% per °C” (Effect of Temperature), which is higher than the datasheet’s 0.04 %/K. At 800 W/m² and 50 °C it gives 2.80 A instead of 2.79 A. The difference is too small to matter.
The measurement error is far larger. PVEducation states that “ISC might be out by 50% or more” (PVEducation). That source does not list the causes. Without an irradiance meter, though, the expected value is itself uncertain: the 800 W/m² in this example is an assumption, not a measurement. A multimeter Isc reading can catch a module that is badly wrong. It cannot grade one that is a little low.
How to read the results: pass, marginal or fail
The limits in this table come from PVEducation’s stated accuracy: about 10% for Voc and as much as 50% for Isc. They are not taken from a test standard. The SM55 column assumes a 50 °C back sheet and about 800 W/m².
| Reading pattern | SM55 example | Likely cause | Result | Next step |
|---|---|---|---|---|
| Voc within about 10% of the corrected value; Isc near the scaled value | 17.8–21.8 V; about 2.8 A | Cells and wiring intact | Pass (multimeter stage only) | Load test |
| Voc more than about 10% low but well above zero; Isc normal | Below about 17.8 V | Shorted bypass diode, or a group of cells cut out of the string | Fail until explained | Open the junction box and check the diodes |
| Voc near 0 V | Near 0 V | Open circuit: broken lead, failed junction-box connection or broken cell connection | Fail | Inspect the leads and the junction box |
| Voc normal; Isc below about half the scaled value in full, unshaded sun | Below about 1.4 A | Heavy browning, dirt, cracked cells, or less light than assumed | Marginal | Clean the glass, retest near midday, then load test |
| Voc and Isc normal; low current under load | See the next section | Raised series resistance, such as failed solder bonds | Fail at load | Compare with the field results below |
The last row is the one a multimeter cannot catch on its own.
Why a panel can pass the multimeter test and still underperform
SUPSI examined SM55 modules after three decades in service and found that “Standard SM55 modules exhibited recurring solder bond failures.” The failed bonds raised series resistance and reduced the fill factor (pv magazine, January 2026). The fill factor is the share of Voc × Isc that a module actually delivers at its maximum power point. Series resistance bends the middle of the current–voltage curve but leaves its two ends, Voc and Isc, close to where they were. A module with failing bonds can therefore read normally at both ends and still produce less power.

The usual shortcut estimate does not help here. Without a full current–voltage curve, PVEducation estimates maximum power as Voc × Isc × FF, with FF around 0.7 (PVEducation). The SM55’s datasheet fill factor is 55 W ÷ (21.7 V × 3.45 A) ≈ 0.73. In the 50 °C, 800 W/m² example, that gives 19.8 V × 2.79 A × 0.73 ≈ 40 W. The estimate assumes a healthy fill factor, and a healthy fill factor is exactly what failed solder bonds take away. The calculation returns a normal answer for a faulty module.
A load test measures what the module actually delivers into a real load. It is done in full, unshaded sun:
- An Isc reading and a back-sheet temperature, taken as in Step 3.
- The module reconnected to its charge controller and battery, and the voltage read across the module terminals while it charges.
- The current read with the meter in series in one module lead, red lead in the 10 A socket.
- Voltage × current = power delivered at that moment.
The battery and the controller set the operating voltage, so the result is the power at that voltage. It can be lower than the module’s maximum even when the module is healthy. Current is the better guide. On the SM55 datasheet, current at Vmp is 3.15 A ÷ 3.45 A ≈ 91% of Isc, and at lower voltages a healthy module delivers more current than that. If the module is charging at a voltage below its Vmp, the load current should therefore be close to the Isc read a few minutes earlier. A load current well below about 90% of that reading is what raised series resistance produces. Vmp also falls as the module heats, and the datasheet table used here gives no Vmp temperature coefficient. The 17.4 V figure applies at 25 °C only.
Heat alone reduces power considerably. The curves fitted to the manufacturer’s data put SM55 Pmax at 55.07 W at 1000 W/m² and 25 °C, at 46.01 W at 60 °C (about 16% lower), and at 9.88 W at 200 W/m² (Chaibi et al.). These figures are simulations, not field measurements of aged modules.
How much power should a 30-year-old Siemens or ARCO module still make?
Four long-term data sets cover these module families or the field as a whole. Their results differ widely.
| Study | Modules | Site and climate | Years in service | Loss rate (%/yr) | Result |
|---|---|---|---|---|---|
| SUPSI, six Swiss systems | ARCO AM55; Siemens SM55, SM55-HO, SM75 (48–55 W) | Jungfraujoch, Birg, Mont-Soleil, Burgdorf (two sites), Möhlin | 30–35 | 0.24 average; systems ranged 0.12–0.55 | “Most of the modules still retained at least 80% of their nominal power” |
| Mont-Soleil plant (in the SUPSI paper, as quoted by pv magazine) | Siemens SM55 | 1,270 m, Switzerland | Not stated in the summary | About 0.25 | Secondary figure; the paper itself was not consulted |
| CDER, Algeria | 64 ARCO Solar 43 W, 36 cells, early 1980s | About 20 years in the Adrar desert, then about 10 in Algiers | About 30 | “between 1% and 2%” | Average 22.77 W (about 53% retained); range 15.91–29.75 W |
| NREL, Jordan and Kurtz | “Nearly 2000 degradation rates” from published studies of modules and systems | Many sites, 40 years of literature | Various | 0.5 median | Review across all module types |
The sources disagree on what counts as typical. SUPSI describes −0.75% to −1% per year as the usual figure in the literature. NREL’s review gives a median of 0.5% per year. Neither source addresses the other’s figure, and this page does not try to settle the difference.
The Swiss results apply to particular materials. The pv magazine summary of the SUPSI paper names the bill of materials as the most important factor in how long a module lasted. It also reports that the SM55-HO, whose back sheet had higher internal reflectance, was more stable. SUPSI itself cautions that its rates are “not directly applicable to more recent systems.”
A worked example shows what those rates mean for an SM55. The calculation assumes a simple linear loss: the yearly rate × 30 years, subtracted from 100%.
| Loss rate (%/yr) | Retained after 30 years (%) | SM55 equivalent at STC (W) | Matching data |
|---|---|---|---|
| 0.25 | 92.5 | 50.9 | SUPSI average, Mont-Soleil |
| 0.5 | 85 | 46.8 | NREL median |
| 1 | 70 | 38.5 | CDER low end |
| 2 | 40 | 22.0 | CDER high end |
These are power figures at standard test conditions. A field reading taken at 50 °C under haze will come out lower even on a module at the top of the table. Comparing a field reading directly with the table makes a good module look bad.
Keep the module or replace it?
Some modules should be retired whatever their readings. These include a detached or loose junction box, and a Voc near zero that cannot be traced to a lead or a connection that can be repaired. Insulation is a separate matter. In the CDER set all 64 modules passed the dry insulation test, but only 63% passed the wet-leakage test (pv magazine, September 2026). A multimeter check says nothing about insulation.
A module is worth keeping when its corrected Voc and Isc pass, its load current holds close to its Isc reading, and its output fits a loss of about 1% per year or less. The CDER lead author regards up to 1% per year as acceptable. For a 30-year-old SM55, that line is about 38.5 W at standard test conditions. Field conditions rarely allow that figure to be confirmed exactly, so the line is a guide, not a measurement.
A module between those two cases may still charge a battery at a lower rate. Whether that is enough depends on the load. For a module that fails, replacing a Siemens solar module covers matching voltage and current in an existing array. The SM55/SM50 page lists the full specifications that a replacement has to match.
Common questions about testing old Siemens panels
Do 30-year-old solar panels still work?
Many do, at reduced output. In SUPSI’s study of Swiss AM55 and SM55 systems, “Most of the modules still retained at least 80% of their nominal power” after 30–35 years (SUPSI). The 64 ARCO modules CDER tested after about 30 years averaged 22.77 W from a 43 W rating, about 53% (pv magazine). The two sets are about the same age. They differ in climate and in materials.
What open-circuit voltage should a 36-cell Siemens module read?
An SM55 should read 21.7 V at a 25 °C cell, about 20.6 V at 40 °C, about 19.8 V at 50 °C and about 19.0 V at 60 °C, using the datasheet coefficient of −0.35 %/K. A field reading within about 10% of the corrected value is consistent with a healthy module. Other models use their own datasheet Voc, corrected the same way.
Can an old solar panel be tested on a cloudy day?
Not usefully. PVEducation puts cloudy-day output at “about 10-20% of the rated output” (PVEducation). Isc falls with the light, so a low reading on a cloudy day looks the same as a fault. A Voc near zero still points to an open circuit in any daylight.
Does shorting the leads through a multimeter harm the module?
The risk in the Isc measurement falls on the meter. PVEducation moves the red lead to the 10 A socket “to prevent blowing the fuse.” Isc is a rated datasheet condition, measured with the terminals shorted, and the SM55’s 3.45 A is under a 10 A rating. The measurement is for one disconnected module only. Several modules wired in parallel can together carry more current than the meter is rated for.
Sources and open questions
- Chaibi, Malvoni, Allouhi, Mohamed. Data on the I–V characteristics related to the SM55 monocrystalline PV module at various solar irradiance and temperatures. Data in Brief 26:104527, 2019-09-16. Source of the Shell SM55 datasheet values and the simulated curves.
- PVEducation. Module Measurement without Load.
- PVEducation. Effect of Temperature.
- PVEducation. Nominal Operating Cell Temperature.
- D. C. Jordan and S. R. Kurtz. Photovoltaic Degradation Rates — An Analytical Review. NREL/JA-5200-51664, 2012-06-01.
- SUPSI. Photovoltaic modules designed for the alpine environment, 2026-06-11. Paper: “Three decades, three climates,” DOI 10.1039/D4EL00040D.
- pv magazine. Study finds much lower-than-expected degradation in 1980s and 1990s solar modules, 2026-01-30.
- pv magazine. After 30 years in hot arid climate, Arco Solar modules still deliver about half their original power, 2026-09-18. Paper in Next Energy, lead author Hichem Hafdaoui.
Open questions:
- The SM55’s NOCT, Vmp temperature coefficient and number of cells per bypass diode are not confirmed in the documents used for this page.
- The gap between back-sheet temperature and cell temperature is not quantified in these sources.
- The Mont-Soleil rate of about −0.25% per year is taken from a press summary of the SUPSI paper, not from the paper itself.
- The production years of SM55 modules that used unstabilized encapsulant are not stated in the SUPSI summary.
- The fixed-voltage and load-current checks on this page are derived from datasheet ratios. They are not a published test method.